Chapter 4 103
CDMA Measurements - Screens and Control Fields
Input Port Meas Intvl
Input Port
This field selects which Test Set port to use as the RF input. This field
is not displayed when measuring average power, since you must use the
RF IN/OUT port to measure average power.
CAUTION Instrument Damage
To prevent instrument damage, do not exceed the
maximum power level labeled at the connectors on your
Test Set. The ANT IN connector is for measuring low level
RF signals. High level (>60 mW) transmitter signals must
be measured using the RF IN/OUT port.
Screens on which this field is present
CDMA ANALYZER
CODE DOM (Code Domain Analyzer): main controls menu
Lvl
This measurement displays the relative level of the selected Walsh
channel when compared to the total power in a 1.23 MHz bandwidth
centered around the Tune Freq setting. The measurement is displayed
when the code domain analyzer’s main controls Measurement field is
set to Power or Fast Pwr.
Screens on which this field is present
COD DOM (Code Domain Analyzer): marker controls menu
Meas Intvl
This field determines the length of the data block. The data block is a
time record over which correlated measurements are computed. As the
interval is increased, measurement time is increased. Increasing the
interval gives more accurate measurement results, particularly with
frequency error and phase error measurements.
This field is displayed on the CDMA ANALYZER screen when a rho or
EVM measurement is selected. It is also displayed on the CODE DOM
(Code Domain Analyzer) controls menu.
Screens on which this field is present
CDMA ANALYZER
CODE DOM (Code Domain Analyzer): controls menu
Main Menu