Schneider Electric DS301 Cell Phone User Manual


 
82 Fieldbus interface
8 Object directory IL•1F CANopen DS301
0198441113586, V2.01, 11.2008
Bit coding, subindex 00h
1008h Manufacturer device name
The object specifies the device name (e.g. “IFS ”)
Object description
Value description
100Ch Guard time
The object specifies the time span for node guarding of an NMT slave.
Object description
Value description
Bit Access Value Meaning
0 ro Error! (generic error)
1 ro Current
2ro Voltage
3 ro Temperature
4 ro Communication profile (communication error)
5 ro Device profile (device profile error)
6ro Reserved
7 ro Manufacturer-specific
Index 1008
h
Object name manufacturer device name
Object code VAR
Data type String
Subindex 00
h
, manufacturer device name
Meaning Manufacturer name
Access read-only
PDO mapping
Value range
Default value
Can be saved
Index 100C
h
Object name guard time
Object code VAR
Data type Unsigned16
Subindex 00
h
, guard time
Meaning Time span for node guarding [ms]
Access read-write
PDO mapping
Value range 0...65535
Default value 0
Can be saved