40
(1) Rotational Sensor Adjustment
Distance Adjustment;
• Pull the rotational sensor as far away from the basket (tumbler) as possible.
• Spin/rotate the basket (tumbler) until the target (target lines up behind one of the basket ribs)
is aligned with the rotational sensor.
Mark basket (tumbler) rib with tape.
• The rotational sensor
has to be adjusted towards
the target until there is a 3/16" gap.
Time Adjustment;
• Jog basket (tumbler) for 10-seconds.
• Time the rotational sensor (the
time is measured from the last
time the target (tapered rib) goes
by the rotational sensor and the indicator light
on the sensor goes out.
• The measured time
has to be 12-seconds.
• If an adjustment is required, remove the adjustment cap on the proximity sensor.
• Turn potentiometer on the proximity sensor
• Retime the sensor.
• Adjust as needed.
11) Reinstall the left tilt guard removed in Step #3 (refer to previous page [page 39]).
12) Reinstall the tumbler (basket) section bottom left hand panel removed in Step #2 (refer to previous
page [page 39]).