Section 5 User Interface Guide TRACER 6000 Series Integrated System Manual
88 Copyright © 2005 ADTRAN, Inc. 612806420L1-1F
displays only during an active alarm condition. Once the condition has cleared, the speed alarm is cleared
from the display. A
FAN HAS FAILED display indicates that the fan has reported a low speed consistently
and is declared as bad and should be replaced. The
FAN HAS FAILED alarm displays until manually cleared
from the system (using the
PERSISTENT ALARMS menu). Figure 36 on page 88 provides an example fan
alarms.
Figure 36. Active Fan Alarm
> SYSTEM ALARMS > TEMP ALARMS
Displays temperature alarm information for the system. A TEMPERATURE ALARM is indicated when the
system detects that the internal system temperature is elevated above normal operation. The
TEMPERATURE
A
LARM displays only during an active alarm condition. Once the condition has cleared, the alarm is cleared
from the display. The
TEMPERATURE ALARM RECORDED display indicates that a TEMPERATURE ALARM has
occurred after the last manual alarm clear. The
TEMPERATURE ALARM RECORDED displays until manually
cleared from the system (using the
PERSISTENT ALARMS menu). The TRANSMITTER SHUTDOWN failure
indicates that the transmitter is shutting down do to an unresolved temperature failure, or a temperature
failure coupled with both fans failing.
TRANSMITTER SHUTDOWN failures display until manually cleared
from the system (using the
PERSISTENT ALARMS menu).
> SYSTEM ALARMS > PERSISTENT ALARMS
Clears all alarms listed on the SYSTEM ALARMS page that must be cleared manually (such as the FAN HAS
F
AILED, TEMPERATURE ALARM RECORDED, and TRANSMITTER SHUTDOWN failures).
A TRANSMITTER SHUTDOWN failure activates the main alarm relay on the TRACER 64x0
system.