-3-
598-1094-01
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
Least Sensitive Most Sensitive
Sensor
Motion
Motion
The detector is most sensitive to motion across its field
of view.
❒ Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
❒ Adjust the RANGE as
needed. RANGE set too high
may increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of ON-TIME
you want the lights to stay on
after motion is detected (1, 5, or 20 minutes).
❒ Set the DUAL LIGHT LEVEL switch to the amount
of time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5
m) with Range Boost [varies
with surrounding temperature].
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300 Watts Incandescent
Maximum [Up to 150 Watts
Maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1 , 5, 20 minutes
Dual Light Level . . . . Off, 3, 6 Hours, Dusk-to-Dawn
Atlas Lighting Products, Inc. reserves the right to discon-
tinue products and to change specifications at any time
without incurring any obligation to incorporate new fea-
tures in products previously sold.
Maximum Range Maximum
Coverage Angle
NOTE: Sensor has about 1
1
/
2
minutes warm up
period before it will detect motion. When first
turned on, wait about 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
240°
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME DUAL BRITE
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
❒ Turn the RANGE control to the mid position,
DUAL LIGHT LEVEL to OFF, and the ON-TIME
control to the TEST position.
100 ft.
(30.5 m)
Boosted
DUAL LIGHT LEVEL