A SERVICE OF

logo

-3-
598-1094-01
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Least Sensitive Most Sensitive
Sensor
Motion
Motion
The detector is most sensitive to motion across its field
of view.
Loosen the clamp screw in
the sensor ball joint and gen-
tly rotate the sensor.
Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cov-
erage area. Keep the sensor
at least 1" (2.5 cm) away
from the lamps.
Adjust the RANGE as
needed. RANGE set too high
may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of ON-TIME
you want the lights to stay on
after motion is detected (1, 5, or 20 minutes).
Set the DUAL LIGHT LEVEL switch to the amount
of time after dusk you want the lights on at low level
(Off, 3, 6 Hrs., Dusk-to-Dawn).
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5
m) with Range Boost [varies
with surrounding temperature].
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300 Watts Incandescent
Maximum [Up to 150 Watts
Maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1 , 5, 20 minutes
Dual Light Level . . . . Off, 3, 6 Hours, Dusk-to-Dawn
Atlas Lighting Products, Inc. reserves the right to discon-
tinue products and to change specifications at any time
without incurring any obligation to incorporate new fea-
tures in products previously sold.
Maximum Range Maximum
Coverage Angle
NOTE: Sensor has about 1
1
/
2
minutes warm up
period before it will detect motion. When first
turned on, wait about 1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
70 ft.
(21 m)
8 ft.
(2.4 m)
240°
B
O
O
S
T
MAX
MIN
RANGE
ON - TIME DUAL BRITE
TEST 1 5 20
MINUTES
OFF 3 6 DUSK TO
HOUR DAWN
Turn the RANGE control to the mid position,
DUAL LIGHT LEVEL to OFF, and the ON-TIME
control to the TEST position.
100 ft.
(30.5 m)
Boosted
DUAL LIGHT LEVEL