and or single injector. To learn tach;
1. Start with the programming switch in the OFF position.
2. Turn the ignition key to the ON position.
3. Flip the program switch ON - OFF - ON - OFF - ON - then OFF.
4. Immediately turn the ignition key OFF.
5. Flip the program switch ON, then start the vehicle using the ignition key.
6. When the unit senses the tach signal, the parking lights will begin to flash.
7. Flip the program switch OFF. The parking lights will turn on for 3 seconds to indicate that the tach signal is stored
and the unit is now out of the program mode.
3. Diagnostics:
1. Be sure that programmable feature number #7 is set to the "Diagnostics On" mode.
2. First flip the program switch on, then turn the ignition key to the ON position.
3. The lights will flash, and number of flashes will indicate the reason for shutdown on the last remote start attempt. The
indications are as follows:
1 Flash 10 or 15 Minute Run Timer Expired
2 Flashes Low or No Tach Signal (RPM)
3 Flashes Positive Or Negative Shutdown Wire Activated
4 Flashes Control Switch Moved to Off Position
5 Flashes RF shutdown, Remote signal received, or manual start trigger wire reactivated.
6 Flashes High RPM Signal Received
7 Flashes Tach Has Not Been Programmed
TIMED START PROGRAM:
The Remote Start unit has the ability to start the vehicle automatically at timed intervals. This feature is useful in
extremely cold climates where starting the engine is the only means to keep the battery charged and fluids warm. The
operator has the option to have the unit start every 2 or 4 hours for a maximum of 48 hours. Factory pre-set is to start at
4 hour intervals. To select 2 or 4 hour automatic start timer:
1. Start with the Enable switch (Red Handle) in the "On" Position.
2. Turn the ignition on then off.
3. Within 10 seconds of the key turning off, cycle the enable switch Off, On, Off, On ( 2 times) to select a 2 hour timed
start interval. Cycle the enable switch Off, On, Off, On, Off, On, Off, On (4 times) to select a 4 hour timed start interval.
The lights will flash 2X or 4X dependant upon 2 or 4 hour interval setting.
NOTE: Once selected, 2 or 4, this timer interval will remain in memory until it is manually changed. To change, the
above sequence will have to be followed.
TIMED START OPERATION:
To begin the start timer, within 10 seconds of turning off the ignition switch, activate the RF command to start 2 times.
(Press button two 4 times). The lights will flash 4 times. Indicating timed interval mode has been initiated. The vehicle
will automatically start every 2 or 4 hours as programmed. To cancel the timed start mode start the vehicle either by RF
or by the ignition key.
Multi Coil Pack Adaptor: (Optional)
The multi coil pack adaptor, (P/N 136B1400), is designed for use with vehicles having multiple ignition coils where a
single point tach signal is unavailable.
To use the adaptor, the Green/Black wires must connect to the negative side of the ignition coil(s).
1. For vehicles utilizing independent coils per cylinder, connect the three Green/Black leads to alternate coils. To
achieve optimum performance the coil signals must be evenly distributed. This is accomplished by first mapping out
the firing order of the engine in groups of as indicated below. Draw a circle around any of the columns. The Green/
Black wires should be connected to the negative (-) terminal of the respective cylinder number which appears in any
of the circles.