A SERVICE OF

logo

®
Page 4
ALLURE
®
QS3 SERIES
RANGE HOOD
PREPARE THE HOOD
11 Remove appropriate Duct Knockout(s) from top or back of
hood.
REAR
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Horizontal Discharge)
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼” x 10”
Vertical & for 7” Round
Discharge)
SEMI-CIRCULAR
DUCT KNOCKOUT
(Remove for 7” Round
Discharge)
12 Horizontal Discharge Only: Remove the Plate in front of the
horizontal discharge knockout. Cut the Ties, lift plate out,
and discard plate. DO NOT REMOVE the
Metal Strip held in
place with two Screws.
TIES
PLATE
METAL STRIP
SCREW
PREPARE THE HOOD
14 7” Round Ducted Discharge Only: Re-install 7” Round Duct
Plate removed in Step #1 under “PREPARE THE HOOD”.
Install a 7” round damper (purchase separately). Damper
flap must open freely in direction of airflow (away from range
hood).
13 3¼” x 10” Ducted Discharge Only: Remove Tape from
damper flap and attach Damper/Duct Connector over
knockout opening with screws removed in Step 4 under
“PREPARE THE HOOD”. Make sure damper
Pivot is nearest
to Top/Back Edge of hood.
DAMPER/
DUCT
CONNECTOR
(Vertical
discharge
position shown)
TAPE
UP TO 1”
SIDE-TO-SIDE
ADJUSTMENT
PIVOT
TOP/BACK
EDGE
NOTE
To accomodate off-center ductwork, the Damper/Duct
Connector can be installed up to 1-inch on either side
of hood center or the 7” Round Duct Plate can be installed up to ½”
on either side of hood center. In extreme off-center installations,
one end of the duct connector may need to be trimmed to clear the
electrical cable clamp.