GRYPHON™
132
5
5.9.2 Copy GRYPHON
M-Series
Procedure:
Using the
slave
reader and its OM-GRYPHON™ cradle, follow the initialization
procedure in chapter 4 of this manual or from the Quick Reference Manual.
With the
master
GRYPHON
M (correctly configured reader), read the Copy
Configuration barcode below. Then place it onto an OM-GRYPHON™ cradle
within 10 seconds. The reader will beep indicating the configuration has been
copied.
The configuration will be simultaneously sent over the RS232 interface of the
OM-GRYPHON™. If this causes undesired effects disconnect the RS232 cable
between the PC and OM-GRYPHON™ during this process.
Copy Configuration
i;;k
i;;k
i;;k
$+ZZ0$-
With the
slave
GRYPHON
M, read the Get Configuration barcode below.
Then place it onto the
same
OM-GRYPHON™ cradle used in the step above.
The slave reader's address will not be changed
.
Get Configuration
i;;k
i;;k
i;;k
$+ZZ2$-
The configuration will be copied from the master to the slave GRYPHON
M. The
slave GRYPHON
M signals the end of the procedure with a series of beeps. It is
now ready to be used with its own OM-GRYPHON™ cradle.
Repeat the procedure above to configure other slave readers. The
OM-GRYPHON™ can continue to configure slave readers until it receives
another command or data.