General
User interface Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and
Spanish
LEDs Four status-indicating LEDs
Topology Double-conversion
Diagnostics Full system self-test
UPS bypass Automatic bypass
Dimensions See models selection guide
Rail kit Included with all units
Electrical Input
Nominal voltage 230V
220V-240V
user selectable
Voltage range 156–280 Vac (output PF 0.7)
Power draw of UPS
(full load)
6000VA: 26A @230V
Recommended input-
breaker rating
35A
Frequency 50/60 Hz autoselect
Frequency range 40–70 Hz
Electrical Output
Power factor 0.7
On utility voltage ±2% of nominal regulation
On battery voltage ±2% of nominal regulation
Efficiency >97% in high-efficiency mode; 91% in normal mode
Frequency regulation ±3% Hz online
Load crest factor 3 to 1
Battery
Internal battery type 5.5Ah, sealed, lead-acid; maintenance free
Externa battery
modules
Up to four per 9135, rail kits included for rack
mounting
EBM battery type 5.5 Ah, sealed, lead-acid; maintenance free
Battery runtime Four (4) minutes with internal batteries @100% load
(0.7 PF)
For additional details, see battery runtime chart
Battery recharge
time
Six (6) hours to recover 90 percent of nominal backup
time after 100 percent RCD load discharge
Battery replacement Hot-swappable internal and external batteries
Start-on-battery Allows start of UPS without utility input
Communications
Serial port RS-232 standard, RS-232 cable provided
USB port HID standard, for communicating with Windows XP/
Vista
Relay output DB-9 Dry Contact-common alarm standard
Software Intelligent Power Manager (IPM) and IPP
Optional
communication
cards
ConnectUPS-MS Network Management Card for direct
control and monitoring in SNMP-based ne works
ConnectUPS-MS Card with ModBus RTU interface
Serial Management Card-MS for integration to indus-
trial environment and building management systems,
remote shutdown for IBM AS/400 systems
Environmental
Safety markings CE, GS
EMC IEC/EN 62 040-2 class A
Audible noise Max 46 dB
Ambient operating 0˚C to +40˚C
Storage temperature -20˚C to +40˚C with batteries and
-25˚C to +55˚C without batteries
Relative humidity 5–90% non-condensing
In the interests of continual product improvement all specifications are subject to change without notice.
Eaton 9135 UPS Product Focus
TECHNICAL SPECIFICATIONS
Heat Dissipation (BTUs/hr)
Operating mode Efficiency 5 kVA 6 kVA
Normal 91% 1150 1350
Battery 86% 1650 1960
High efficiency 97% 370 450