![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/43/d43b521d-9a25-b2d4-218b-5210640a40e5/d43b521d-9a25-b2d4-218b-5210640a40e5-bg2c.png)
Design Spot 575E™
©Elation Professional® 44
Design Spot 575E™
Gobo Rotation Er
(Gobo Rotation wheel 1- error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 1
is not located in the default position after the reset.
Rotation gobo Er
(Rotating gobo wheel 2- error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective ( or its driving IC on the main PCB). The Rotating gobo wheel 2
is not located in the default position after the reset.
Gobo Rotation Er
(Gobo Rotation wheel 2- error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective ( or its driving IC on the main PCB). The Gobo Rotation wheel 2
is not located in the default position after the reset.
Prism Rotation Er
(Prism Rotation-wheel error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective ( or its driving IC on the main PCB). The Prism Rotation -wheel is
not located in the default position after the reset.
Shutter, Strobe Er
(Shutter, Strobe-wheel error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Shutter, Strobe -wheel is
not located in the default position after the reset.
Focus Er
(Focus error) This message will appear after the reset of the fixture if the yoke’s