A SERVICE OF

logo

ESC/VP Level 6 Serial Communication Manual (Abridged Edition)
19 of 20
11 : Message
Controls the screen state when no signal is input.
[Parameter]
Data relating to screen state when no signal is input
0x00: Non-display
0x01: Black
0x02: Blue
0x03: Logo
Set
1D 0009 01 01 06 11 PARA CS 1D
0008
000A
81
C1
10 06 11
--
PARA
CS
Get
1D 0008 02 01 06 11 -- CS 1D
0009
000A
82
C2
10 06 11 PARA CS
Initialize
1D 0008 03 01 06 11 -- CS 1D
0009
000A
83
C3
10 06 11 PARA CS
14 : V Keystone
Adjusts the projected image in the vertical direction during keystone correction.
[Parameter]
Vertical Keystone Value (1 byte)
Setting range: 80 to FF, 00 to 7F
Set
1D 0009 01 01 06 14 PARA CS 1D
0008
000A
81
C1
10 06 14
--
PARA
CS
Get 1D 0008 02 01 06 14 -- CS 1D
0009
000A
82
C2
10 06 14 PARA CS
Initialize 1D 0008 03 01 06 14 -- CS 1D
0009
000A
83
C3
10 06 14 PARA CS
15 : DelayON (Applicable models: EMP-8100/8150/9100/7700)
Controls the DelayOn ON/OFF setting.
When set to ON, the lamp is on when power is being supplied through the power cable. When set to OFF, this function is disabled.
[Parameter]
Data relating to DelayON ON/OFF setting (1 byte)
0x00: OFF
0x01: ON
Set
1D 0009 01 01 06 15 PARA CS 1D
0008
000A
81
C1
10 06 15
--
PARA
CS
Get
1D 0008 02 01 06 15 -- CS 1D
0009
000A
82
C2
10 06 15 PARA CS
Initialize
1D 0008 03 01 06 15 -- CS 1D
0009
000A
83
C3
10 06 15 PARA CS
16 : Comp1/DV1 selection
Sets the Computer1 or DVI image bus independent of he I/F panel slide switch setting.
Gets the current image bus setting (Computer or DVI).
[Parameter]
Data relating to image bus setting (1 byte)
0x00: Computer1
0x01: DVI
Set
1D 0009 01 01 06 16 PARA CS 1D
0008
000A
81
C1
10 06 16
--
PARA
CS
Get 1D 0008 02 01 06 16 -- CS 1D
0009
000A
82
C2
10 06 16 PARA CS
19 : Computer2 input format (Applicable models: EMP-7600/5600)
Controls the input format for the Computer2 terminal.
[Parameter]
Data relating to Computer2 terminal input format
0x00: RGB
0x01: YCbCr
0x02: YPbCr
Set
1D 0008 01 01 06 19 PARA CS 1D
0008
000A
81
C1
10 06 19
--
PARA
CS
Get
1D 0008 02 01 06 19 -- CS 1D
0009
000A
82
C2
10 06 19 PARA CS
Initialize
1D 0008 03 01 06 19 -- CS 1D
0009
000A
83
C3
10 06 19 PARA CS
06 OPTION
Command
structure
Type
Apply Reply
STX Size
Attribu
te
From
To
Group Item
Param
eter
Check-
sum
STX Size
Attribu
te
From
To
Group Item
Param
eter
Check-
sum