382400-EN-V1.2-3/12
6
DATA HOLD, MAX-MIN, and PEAK Modes
1. Measure current or voltage as previously described.
2. Press the HOLD button to access the Data Hold mode; an H icon will be displayed. Use the
Data Hold mode to freeze a displayed reading.
3. Press again to access the MAX mode. In the MAX mode, only the highest reading will be
displayed. The MAX icon will be indicated on the LCD display.
4. Press again to access the MIN mode. In the MIN mode, only the lowest reading will be
displayed. The MIN icon will be indicated on the LCD display.
5. Press again to access the PEAK mode. The PEAK display icon will be indicated on the LCD
display.
6. Press and hold the HOLD button for 3 seconds to return to the normal operating mode.
Note: The sampling time of the PEAK Mode is 39µS (50Hz) or 33µS (60Hz).
HOLD, MAX and MIN display the TRMS value
Automatic Power OFF
In order to conserve battery life, the meter will automatically turn off after approximately 15 minutes.
To turn the meter on again, turn the function switch to the OFF position and then to the desired
function position.