CABLES
IMPORTANT
• Use only 1.00mm
2
size cable up to 40 metres length
maximum.
Maximum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
• YOUR HEDGETRIMMER IS SUPPLIED WITH
CABLE WIRED DIRECTLY INTO THE PRODUCT.
1. Mains Cables and Extension Cables are available
from your local Approved Service Centre.
2. Do not wire an extension cable directly to your prod-
uct yourself. Please contact your local Approved
Service Centre for further information on the connec-
tors and kits available.
3. Only use extension cables specifically designed for
outdoor use.
CONNECTORS
IMPORTANT
• Connectors are suitable for use with 2 core cable
only. Under no circumstances should these connec-
tors be used for earthed products.
• All connectors and cables are of splashproof con-
struction. They are not waterproof and must not be
left outside permanently nor should they be sub-
merged or immersed in water. Do not let cable lay or
trail through pools of water or splashed with water
from hose pipes.
MAINS PLUG REPLACEMENT
IMPORTANT
• If the plug supplied is cut off it should be de-
stroyed. There is an electric shock hazard if a cut
off plug is inserted into a 13 amp socket.
1. No earth required. Our products are double insu-
lated to EN60745 and under no circumstances
should an earth be connected to any part of the prod-
uct.
2. Ensure the mains voltage suits your product
3. IMPORTANT!
The wires in the mains lead are coloured in accor-
dance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured BLUE must be connected
to the Terminal which is marked with the letter 'N' or
coloured BLACK.
The wire which is coloured BROWN must be con-
nected to the Terminal which is marked with the letter
'L' or coloured RED.
4. It is important that the outer sheath is clamped cor-
rectly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only pro-
tect the electrical equipment and are not a safeguard
against electrocution.
If your product is hard wired i.e. non-detachable
mains electric cable, a conversion kit and exten-
sion cable is available from all Approved Service
Centres which can be found in your local Yellow
Pages.
Assembly of Handguard.
1. Insert Handguard into slot as illustrated in figure A,
ensuring that it is securely located.
DO NOT USE THE PRODUCT WITHOUT FIT
-
TING THE HANDGUARD
Assembly
A
Cables