A SERVICE OF

logo

T~
PROBLEM
SOLWR
(continued)
PROBLEM
POSSIBLE CAUSE
WATER LEAKS
Make sure hose connections are
tight
at faucets.
Make sure end of drain hose is correctly inserted in and secured to drain facility.
WASHER IS NOISY
Q
Make sure washer is level and firm to the floor with rubber foot pads in place and
front jam nuts tight. See your Installation Instructions.
A sharp, distinctive
sound
will be heard at the end of each spin period as the motor
stops and the spin brake inside the transmission “locks in.” This sound is normal.
Heavily unbalanced loads can cause the washer to vibrate excessively during spin,
and may cause it to move from its
originrd
position. In extreme cases (usually occurs
when washing a single, heavy
item
or a small load when water level is set higher than
necessary), the spin basket
may
strike the outer tub, creating a loud but harmless noise.
To correct, stop
the
washer by pushing in the Cycle Selector knob, open the lid and
redistribute the load
evenly
about the wash basket. Close the lid and restart.
I
WASHER PAUSES
Washer normally pauses between washing
steps..,such
as between wash and spin or
IN
CYCLE
between spin and rinse.
If you
need more
help...call,
toll free:
GE
Answer Center” /
800.626.2000 /
consumer information service
CARE
Am
CLEAN~G
USER MAINTENANCE INSTRUCTIONS
The Tub.
The porcelain is self-cleaning. Leave lid
To Store Washer.
Ask service technician to remove
open after washing to allow moisture to evaporate.
water from drain pump and hoses to prevent freezing.
Do not use harsh or gritty cleansers.
Do not store the washer where it will be exposed
The Exterior.
Wipe off any spills of washing
to the weather.
compounds. Wipe or dust with damp cloth. Try
For Long Vacations.
Be sure water supply is shut off
not to hit surface with sharp objects.
at faucets and drain all water from hoses if weather
will be below freezing.
How to remove the agitator
To remove limestone from
Filter-Flo
pan
To remove the agitator,
snap the cap off and remove
the screw. Then remove
the agitator extender (on
models so equipped)
and
the agitator.
To replace the agitator,
carefully lower it straight
down onto the shaft so
that it fits snugly into
place. Replace the agitator
extender (on models so
equipped), the screw
and the cap.
m
Cap
Soak filter pan in a preheated
160°F.
(71 ‘C.)
w—
B–
Screw
solution of half vinegar and half water for 15
Agitator
minutes. Then brush each side of pan with a stiff
Extender
bristle brush while flushing with running water.
A
(on some models)
— Agitator
)
CAUTIONS:
Do not soak
in porcelain container. Vinegar
can damage porcelain.
A
Do not exceed
180°F.
(82°C.
) or filter pan
Shah
may warp.
.-
(Appearance
may vary)
18