A SERVICE OF

logo

Specifications 97
Rated peak power
For more information, see “Power
supply specifications (on page
97).”
*The system input requirements are based on measurements using hardware available at the publication of this
document. For updated information, see the HP website (http://www.hp.com/go/proliant-energy-efficient).
Power supply specifications
The following specifications provide information on the parameters of the power supplies as they were
designed. For more information on configuring power for a specific server, see the HP website
(http://www.hp.com/go/proliant-energy-efficient).
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100V to 120V AC
200V to 240V AC
Rated input frequency
50Hz to 60Hz
Rated input current
5.5A at 100V AC
2.6A at 200V AC
Rated input power
526 W at 100V AC input
505 W at 200V AC input
BTUs per hour
1794 at 100V AC input
1725 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Rated peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100V to 120V AC
200V to 240V AC
Rated input frequency
50Hz to 60Hz
Rated input current
8.9A at 100V AC
4.3A at 200V AC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input