![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/e0/1e0516ee-eb5b-4d66-aaf6-3670d21f03fc/1e0516ee-eb5b-4d66-aaf6-3670d21f03fc-bg55.png)
Specifications 85
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
°
°
°
°
Nonoperating
-30°C to 60°C (-22°F to 140°F)
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
10% to 90%
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification Value
Height
4.32 cm (1.70 in)
Depth for models with LFF drive cage
75.00 cm (29.50 in)
Depth for models with SFF drive cage
Width
43.46 cm (17.11 in)
Weight (approximate range)
10.00 kg to 24.00 kg (22.00 lb to 53.00 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
• HP 350 W 1U Factory Integrated Power Supply
• HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
• HP 460 W CS Platinum Plus Hot-plug Power Supply (94% efficiency)
HP 350 W 1U Factory Integrated Power Supply
Specification Value
Input requirements
—
Rated input voltage
100 V AC–240 V AC
Rated input frequency
50 Hz–60 Hz