Hardware options installation 47
For more information about the controller and its features, see the HP Smart Array Controllers for HP ProLiant
Servers User Guide on the HP website (http://www.hp.com/support/SAC_UG_ProLiantServers_en). To
configure arrays, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP
website (http://www.hp.com/support/CASAC_RG_en).
Installing the FBWC module and capacitor pack
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the external drives as failed when the server is powered up.
To install the component:
1. Power down the server (on page 15).
2. Disconnect the power cord from the AC source.
3. Disconnect the power cord from the server.
4. Remove the chassis cover (on page 19).
5. Install the storage controller ("Installing a storage controller" on page 46).
6. Install the cache module on the storage controller.
7. Install the capacitor pack:
a. Open the capacitor pack holder.
b. Position the capacitor pack between the two vertical tabs near the holder.
c. Close the capacitor pack holder.