A SERVICE OF

logo

Specifications 82
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -40°C to 70°C (-40°F to 158°F)
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Non-operating 5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Tower server specifications
Specification Value
Dimension
Height (without tower feet) 44.45 cm (17.50 in)
Height (with tower feet) 46.7 cm (18.375 in)
Depth (with tower bezel) 60 cm (23.6 in)
Width 22 cm (8.66 in)
Weight (no drives installed) 27.22 kg (60 lb)
Models with a redundant
power supply
Input requirement
Rated input voltage 100 VAC to 240 VAC
Rated input frequency 47 Hz to 63 Hz
Rated input current 10 A (110 V) to 5 A (220 V)
Rated input power 893 W
BTUs per hour 3049
Power supply output
Rated steady-state power 800 W (low line), 1000 W (high
line)