McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 39
Zoning limits and properties
Zoning limits vary depending on the firmware installed on the switch. To view zoning limits and properties
on a switch:
1. Select Zoning > Edit Zoning to open the Edit Zoning dialog.
2. Choose one of the following:
• Right-click on the top zonesets entry, a zone set, a zone, or a zone member in the zone sets tree (left
windowpane). Select Properties in the popup menu.
• Select the top zone sets entry, a zone set, a zone, or a zone member in the zone set tree (left
windowpane). Select Edit > Properties.
3. View the zoning limits and properties information in the Properties dialog.
4. Click OK to close the Properties dialog.
The zoning limits and definitions are:
• MaxZoneSets is 1. The maximum number of zone sets that can be configured on the switch. This will be
enforced during the configuration of zoning and during a zoning database merge from the fabric.
• MaxZones is 2047. The maximum number of zones that can be configured on the switch. This will be
enforced during the configuration of zoning and during a zoning database merge from the fabric.
• MaxTotalMembers is 10,000. The maximum number of total zone members that can be configured on
the switch. This will be enforced during the configuration of zoning and during a zoning database
merge from the fabric.
• MaxZonesInZoneSets is 2047. The maximum number of zone linkages to zone sets that can be
configured on the switch. This will be enforced during the configuration of zoning and during a zoning
database merge from the fabric. Every time a zone is added to a zone set this constitutes a linkage.
• MaxMembersPerZone is 4096. The maximum number of zone members that can be added to any zone
on the switch. This will be enforced during the configuration of zoning and during a zoning database
merge from the fabric.