A SERVICE OF

logo

11
GRCRHYW
if your existing
thermostat is marked...
label the wire
with this sticker:
G / F
G
G
W / H / B
W/B
W/B
Y / C* / M / O
Y/0
Y/0
RC / VC
RC
RC
RH / R / VR / 4
RH
RH
24 Volt
24 Volt cool
air conditioning
compressor
heating
fan
Y1
Y1
Y1
heat pump
compressor
Connect Wires and Mount Thermostat to
Wallplate
Straighten bare end of each wire and cut or strip it
to 1/4” maximum. Insert each labeled wire into its
matching terminal.
NOTE: If a wire marked “C” is present, DO NOT connect
it to the thermosat.
Hold the wires in each terminal and tighten the
terminal screws securely, otherwise a loose wire
could cause operational problems with your system
or thermostat.
Push excess wire back into hole to prevent
interference with mounting of the thermostat.
Make sure the Thermostats System Switch is set to
OFF.
Insert two AA size alkaline batteries, observing the
polarity marked on the unit.