1 - 20 Modular LYNX System 12.05.2003
Connecting the RS-485 Interface
Single Controller System
In a Single Controller System, the RS-485 interface option would be used if the Control Module is located at
a distance greater than 50 feet from the Host PC. Since most PC’s do not come with an RS-485 board pre-
installed, you will have to install an RS-485 board in an open slot in your PC, or purchase an RS-232 to RS-
485 converter, such as the CV-3222 sold by IMS, to use this connection interface. For wiring and connection
information please use the following table and diagram:
Table 5.4: RS-485 Interface Connections
Figure 5.3: RS-485 Interface, Single Controller System
rodraoB584-SR
retrevnoC584-SRot232SR
eludoMrellortnoCXNYL
)-XR(ataDevieceR9niP)-XT(ataDtimsnarT
)+XR(ataDevieceR 01niP)+XT(ataDtimsnarT
)-XT(ataDtimsnarT7niP)-XR(ataDevieceR
)+XT(ataDtimsnarT 8niP)+XR(ataDevieceR
dnuorGsnoitacinummoC11niPdnuorGsnoitacinummoC
LYNX Control Module
CGND
RX
TX
Host PC
RS-232 To RS-485 Converter
Recommended IMS Part # CV-3222*
If your PC is equipped with an RS-485 Board
no converter is necessary. Connect RS-485
lines directly to Host PC as shown.