Holdcouplingnutandregulator
asshownfor properconnection
toLP tankvalve.
Leak Testing Valves, Hoseand Regulator
1.Turn all grill control knobsto OFF.
2.Be sure regulator is tightly connected to LP tank.
&Completely open LP tank valve by turning OPD hand wheel
counterclockwise. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection. Correct
before proceeding by calling Sears for replacement parts at
1-800-4-MY-HOME@.
4.Brushsoapy solution onto areas where bubbles are shown in
picture below:
6. Turn the coupling nut clockwise and tighten to a full stop. The
regulatorwill seat on the back-checkfeature in the LP tank
valve, resulting in some resistance. An additional one-half
to three-quarters turn is required to complete the
connection. Tighten by hand only - do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator
and repeatsteps 5 and 6. If you are still unable to complete the
connection, do not use this regulatod
Call 1-800-4-MY-HOME¢ for an identical replacement part.
• Do not insert any tool or foreign object into the valve
outlet or safety reliefvalve. You may damage the valve
and cause a leak. Leaking propane may result in
explosion, fire, severe personal injury, or death.
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
• Never attempt to attach this grill to the self-contained
LP gas system of a camper trailer or motor home.
• Do not use grill until leak-tested.
• If a leak is detected at any time, STOPand call the fire
department.
• If you cannot stop a gas leak, immediately close
LP cylinder valve and call LP gas supplier or your fire
department!
6 °640-01303702-3-58
5. If "growing" bubbles appear, there is a leak. Close LP tank
valve immediately and retighten connections. If leaks cannot
be stopped do not try to repair. Call Sears for replacement
parts at 1-800-4-MY-HOME¢.
6. Always close LP tank valve after performing leak test
by turning hand wheel clockwise.