Membrane Filter Elements
Status: 06/2001/01 Operating Manual 15
The following illustration shows the fixed handle for lateral guidance of the filter elements:
Positioning
Position the fixed side so that the filter elements remain centred in the press frame at
operating temperature.
Check the following points when installing the filter elements in the side
bar filter press:
The fixed and loose side of the handles must be properly arranged
Filter elements between the side bars must not jam, even after thermal expansion.
Fixed handle on round side bar Fixed handle on rectangular side bar
Checking:
Check the lateral and height offset of the filter elements to each other.
- Differences of up to 5 mm are permitted.
- The fixed head piece and movable pressure/end piece of the filter press completely
support the head and tail (end) filter elements.
Warning
An impermissible offset and insufficient support of the filter elements lead to
chamber leakage.
Insufficient power transmission on the surface also results in damage to the filter
elements.
Personal injuries and property damage are at risk.
WARNING