1) Positioning parameter
• Positioning parameter setting
• Parameter should be assigned for each axis
(1) Basic parameter
(A) Acceleration/Deceleration time
• This is applied at the starting/ending point of positioning operation, return to origin high speed, and JOG high speed
operation
• The setting range is 0 ∼ 10,000 (unit: 1ms) for each axis.
• When set to zero, operates constant speed.
① Acceleration time : the time required to reach from speed “0”(stop state) to the speed limit which is set by
parameter. In case of using BIAS, it is the time required to reach from the bias speed to the speed limit which is
set by parameter.
② Deceleration time : the time required to reach from the speed limit set by parameter to the speed “0”(stop state).
In case of using BIAS, it is the time required to reach from the speed limit set by parameter to the setting bias
speed.
ctual
cce
era
on
time
ctual acceleration time Time
Setting speed
Speed limit
Speed
ece
era
on
time
Basic
arameter
- Speed limit : max. speed available
to set for positionin
operation a
the parameter of KGLWIN.
- Settin
speed : speed value o
operation data that position data
operates actually.
-
ctual acceleration time : the time
required to reach from speed
“0”(stop state
to the speed value
which is set by operation data.
-
ctual deceleration time : the time
required to reach from the speed
value set b
operation data to