3 - 1
3
SETTING PARAMETERS
This chapter describes the method used to set
the parameters required to use the EV
Counter.
3.1 Setting Parameters (with D-EV)
Before using the EV Counter, various parameters must be set
up. This section explains the setup method using the essential
parameters, "gage resolution" (for EV-16P and EV-16Z) and
"designation of available axes", as examples.
NOTE For the resolution of 0.1ยตm setting, a D-EV is absolutely
necessary.
3.1.1 Parameter mode ON
Set the parameter mode to ON to modify the existing parameter
settings.
(1) Press the P.SET key while holding down the Fn key to set
the parameter mode to ON.
[Display on the D-EV]
UNIT
+NG
GO
-NG
(2) Press the P.SET key one more time to modify the setup
value to 1.
[Display on the D-EV]
UNIT
+NG
GO
-NG
NOTE If a parameter setting needs to be modified, first modify
the setting of Parameter 00 to 1. Parameter modification
cannot be attempted while the setting of Parameter 00 is
0 (Reference mode).
(3) Begin setting the parameters.