SGW-250SS DC WELDER/AC GENERATOR PARTS & OPERATION MANUAL REV. #2 (08/08/01) PAGE 23
General Inspection Prior to Operation
The SGW-250SS utilizes a generator that has been thoroughly
inspected and accepted prior to shipment from the factory.
However, be sure to check for damaged parts or components,
or loose nuts and bolts, which could have occurred in transit.
Ground
The nut and ground terminal on the generator should always
be used to connect the generator to a suitable ground. The
ground path should be of #8 size wire.
Connect the terminal of the ground wire between the lock
washer and the nut and tighten the nut fully. Connect their
end of the wire to a suitable ground.
Circuit Breaker
To protect the generator from an overload, a 2-pole, 30 amp,
circuit breaker is provided. Make sure to switch the circuit
breaker to the "OFF" position prior to starting the engine.
Extension Cable
When electric power is to be provided to various tools or
loads at some distance from the generator, extension cords
are normally used. Cables should be sized to allow for
distance in length and amperage so that the voltage drop
between the generator and point of use (load) is held to a
minimum. Use the cable selection chart (Table 3 ) as a guide
for selecting proper cable size.
SGW-250SS PRE-SETUP
elbaCrotareneG.7elbaT
nitnerruC
serepmA
sttaWnIdaoLhtgneLelbaCelbawollAmumixaM
021tA
stloV
042tA
stloV
eriW01#eriW21#eriW41#eriW61#
5.2003006.tf0001.tf006.tf573.tf052
50060021.tf005.tf003.tf002.tf521
5.70090081.tf053.tf002.tf521.tf001
0100210042.tf052.tf051.tf001
5100810063.tf051.tf001.tf56
0200420084.tf521.tf57.tf05
.egatlovwolmorftlusernacegamadtnempiuqE:NOITUAC