A SERVICE OF

logo

52
Piping Length Characteristic Heating
[Condition] Room temperature: 68°F (DBT)
Operation condition: High fan speed
Outdoor temperature: 47°F (DBT), 43°F (WBT)
Compressor Freq: Fh
A) Indoor unit capacity: Heating (2.8 + 2.8: CS-E9NKUAW + CS-E9NKUAW), service mode frequency = 65Hz
5.700
5.800
5.900
6.000
6.100
9141924293439444954596469747984
Piping Length (ft)
Heating
Capacity (kW)
100.400
101.400
102.400
103.400
104.400
9 141924293439444954596469747984
Piping Length (ft)
Gas Side Piping
Pressure (PSI)
96.500
96.600
96.700
96.800
96.900
97.000
9 141924293439444954596469747984
Piping Length (ft)
Outlet Air
Temperature (°F
)
208 230
7.600
7.800
8.000
8.200
8.400
8.600
9141924293439444954596469747984
Piping Length (ft)
Current
(A)