3) 2 coil latching
*Pulse drive (JIS C 5442-1986)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
REFERENCE DATA
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. allowable voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3V DC
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
66.7mA 66.7mA 45 45
200mW 200mW
150%V of
nominal voltage
4.5V DC 44.4mA 44.4mA 101.2 101.2
5V DC 40mA 40mA 125 125
6V DC 33.3mA 33.3mA 180 180
9V DC 22.2mA 22.2mA 405 405
12V DC 16.7mA 16.7mA 720 720
24V DC 12.5mA 12.5mA 1,920 1,920 300mW 300mW
120%V of
nominal voltage
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 60 m (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Nominal switching capacity (resistive load) 1 A 30 V DC, 0.5 A 125 V AC
Max. switching power (resistive load) 30 W (DC), 62.5 VA (AC)
Max. switching voltage 110 V DC,125 V AC
Max. switching current 1 A
Min. switching capacity (Reference value)*
1
10µA 10mV DC
Nominal operating
power
Single side stable 140 mW (3 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
1 coil latching 100 mW (3 to 12 V DC), 150 mW (24 V DC)
2 coil latching 200 mW (3 to 12 V DC), 300 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact sets 1,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160µs) (FCC Part 68)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20°C 68°F) Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 3 ms [Max. 3 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 490 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 10
8
(at 180 cpm)
Electrical Min. 2×10
5
(1 A 30 V DC resistive), Min. 10
5
(0.5 A 125 V AC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature: –40°C to 70°C –40°F to 158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 1.5 g .053 oz
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TN2-12V, 10 pcs.
30
100
200
1.0
0.5
0.4
0.3
0.2
Switching voltage,V
Switching current, A
DC load (cosϕ=1)
AC load (cosϕ=1)
100
10
0
0.5
1.0
Switching current, A
No. of operations, ×10
4
125 V AC resistive load
30 V DC resistive load
10
100
1,000 10,000
0
10
20
30
40
50
60
70
80
90
100
Ratio against the rated voltage, %V
No. of operations, ×10
4
Max.
Max.
Min.
Min.
Pick-up voltage
Drop-out voltage