30 C1645M-A (9/06)
OPTICAL POWER BUDGET, TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT
Model No.
Wavelength
Optical
Power
Budget
Maximum
Transmission
Distance
Laser
Class 1
Limit*Transmitter
Compatible
Receiver
Multimode (62.5/125 µm)
FT85041MSTR FR85041MSTR 1310 nm (video)
20 dB
†
2 km (1.2 mi)
‡
<15.6 mW
850 nm (data)
20 dB
†
2 km (1.2 mi)
‡
<0.78 mW
Single-Mode (9/125 µm)
FT85041SSTR FR85041SSTR 1310 nm (video) 20 dB
30 km (18.6 mi)
§
<15.6 mW
1550 nm (data) 20 dB
30 km (18.6 mi)
§
<10.0 mW
FT85041SFCR FR85041SFCR 1310 nm (video) 20 dB
30 km (18.6 mi)
§
<15.6 mW
1550 nm (data) 20 dB
30 km (18.6 mi)
§
<10.0 mW
*The FT85041 transmitter and the FR85041 receiver are classified by the FDA as Class 1 laser
products.
†
When using 50/125 µm multimode fiber, subtract 3 dB from the optical power budget.
‡
Maximum transmission distance is limited by fiber bandwidth.
§
Maximum transmission distance is based on attenuation of 0.5 dB/km plus a 5 dB buffer for
connector and splice losses.
NOTES:
• For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT85041MSTR, for example, is CT85041MSTR.
• For models with higher optical power budgets, contact the factory.
The materials used in the manufacture of this document and its components are compliant to the
requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste
electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling
this equipment.
C1645M-A.book Page 30 Wednesday, September 13, 2006 3:07 PM