Care and maintenance
34
Further parameters see manual of the respective drive
10.05.02 Parameter list for control unit MD-4-95-220-CE
Parameter
Description
Setting range
Set value
1
Speed max. 50 - 9999
▲
4
Speed for start backtackl 50 - 8000 1500
5
Speed for end backtack 50 - 8000 1500
40
Thread wiper ON - OFF ON
46
Rotating direction of the motor CW - CCW CW
47
Selected machine class 0 - 101 62
61
Cutting speed 1 50 - 500 220
81
Needle position 6 (start cutting signal 2) 0 - 360° 40°
84
Needle position 5 (end cutting signal 1) 0 - 360° 90°
85
Needle position 9 (start thread tension
release/start thread catcher)
0 - 360° 120°
87
Tension release after thread lever position at t.d.c. 0 - 1500ms 20ms
179
Needle position 2 (take-up lever raised) 0 - 359° 83°
181
Needle position 1 - needle lowered (192 = off) 0 - 255 250
210
Switch on angle for thread trapper 0 - 359° 20°
211
Switch off angle for thread trapper 0 - 359° 90°
236
Machine version
0 = 1183; 1 = 1181
0 - 20
0
Group
Parameter
Description
User lever
Setting range
Set value P40 ED
Set value P40 PD2
9
985 Switch on angle for thread trapper B, C 0 -255 67 67
986 Switch off angle for thread trapper B, C 0 -255 206 206
989 Thread trapper at beginning of seam
1 = yes, 0 = no
B, C 0 - 2 0 0