LEFT/RIGHT HAND CONVERSION:
Refer to (Fig. 1) to determine hand of operator required for
this installation. This unit is factory setup for right hand
operation.
M1 M2
To Motor
To Control
Board
Switch Red And Blue
Wires GoingTo The Motor
To Change Operator
To Left Hand Operation.
Figure 10
To convert operator to left hand operation, make certain the
power switch is off, and locate the motor terminal strip (See
Fig. 10). Switch the red and blue wires, between M1 and M2,
that go to the motor. The operator is now setup for left hand
installation.
24
LIMIT ADJUSTMENT PROCEDURE
WARNING: READ ENTIRE PROCEDURE BEFORE
STARTING. TURN OFF MAIN POWER BEFORE MAKING
ANY ADJUSTMENTS!
WARNING: STAY CLEAR OF ALL MOVING PARTS AND
ELECTRICAL COMPONENTS OF THE OPERATOR WHILE
TESTING!
A CONTROL STATION SUCH AS A THREE BUTTON
STATION (“OPEN”,”CLOSE”,“STOP”) WITH ALL
NORMALLY OPEN CONTACTS IS REQUIRED FOR THIS
PROCEDURE. SEE INSTRUCTIONS BELOW.
456
7
OPEN
CLOSE
STOP
COMMON
1. Connect a wire from the common connection of the
control station to terminal #5.
2. Connect a second wire from the “OPEN” button of
the control station to terminal #6.
3. Connect a third wire from the “CLOSE” button of the
control station to terminal #7.
4. Connect a fourth wire from the “STOP” button of the
control station to terminal #4.