![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/2a/92a135a3-532d-4dbf-991e-259f3790ff0c/92a135a3-532d-4dbf-991e-259f3790ff0c-bg2a.png)
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0842
F. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
• Connect both halves of the storm collar with two screws
(see Figure 10.13).
• Wrap the storm collar around the exposed pipe section
closest to the roof and align brackets. Insert a bolt
(provided) through the brackets and tighten the nut to
complete the storm collar assembly (Figure 10.14). Make
sure the collar is tight against the pipe section.
• Slide the assembled storm collar down the pipe section
until it rests on the roof ashing.
• Caulk around the top of the storm collar (see Figure
10.20).
Figure 10.13 Assembling the Storm Collar
Figure 10.14 Assembling the Storm Collar Around the Pipe