![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/47/c474e35c-b6dc-446c-afa5-f535b66ed869/c474e35c-b6dc-446c-afa5-f535b66ed869-bg23.png)
AirborneDirect™ Users Guide Quatech, Inc.
100-8510-110 2/21/2011 35
12.0 Configuring Device – Industrial Serial (ABDG-SE-IN5XXX)
The following describes initial connection to an AirborneDirect™ Serial Device Server
(ABDG-SE-IN5XXX). If you have an Ethernet device (ABGD-ET-DP5XX/IN5010), please
go to section 14.0. If you have purchased a SE-DP5XX device please go to section 13.0
for the set-up instructions.
The instructions in Table 14 provide step-by-step instructions for configuration of the
ABDG-SE-IN5XXX product family.
Table 14 - SE-IN5XXX Accessing the Web Interface
Open the AirborneDirect™ packaging and locate the Install CD.
Place the CD in the CD/DVD drive of the laptop or desktop you will be using to configure the
AirborneDirect™ device. Follow the on screen directions for installation of the appropriate device
software and documentation.
Connect the Ethernet cable on ABDG to an Ethernet port on the laptop or desktop system.
Apply power to the ABDG-SE-IN5XXX.
The unit will boot and display one of the following LED patterns:
ABDG-SE-IN5XXX
COMM: Off
LINK : Off
POST: Orange
POWER: Blue
Run the Airborne Management System application. This was installed during the CD installation and a
menu item will be found in the Airborne folder located in the programs directory of your system.
When the application opens the following dialog will be displayed:
Select Group Name: manuf and enter Group Password: dpac