![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/1f/81f357c6-f15a-4bd8-8c29-022f6fae6c3b/81f357c6-f15a-4bd8-8c29-022f6fae6c3b-bgc.png)
12
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
Horizontal Venting with Two (2) 90
o
Elbows
Option V H + H1
A) 3' Min. 2' Max.
B) 5' Min. 3' Max.
C) 8' Min. 4' Max.
With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90
o
elbows is required.
INSTALLATION
One 90
o
elbow = Two 45
o
elbows.
Vertical Venting with Two (2) 90
o
Elbows
Option V H V1 V + V1
A) 1' Min. 1' Max. 1' Min. 2' Min.
B) 1' Min. 2' Max. 2' Min. 3' Min.
C) 2' Min. 3' Max. 2' Min. 4' Min.
D) 2' Min. 4' Max. 2' Min. 4' Min.
With these options, max. total pipe length is 30 feet
with min. of 4 feet total vertical and max. 4 feet total
horizontal.
Please note min. 1 foot between 90
o
elbows is
required.
One 90
o
elbow = Two 45
o
elbows.
Vent restrictor position A (fully
open), refer to page 11.
Vent restrictor position A (fully open), refer to
page 11.
Lengths do not include elbow
indicated