ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD
ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD
SECO-LARM U.S.A., Inc.
SECO-LARM U.S.A., Inc.
®
®
PREPARING TO PROGRAM THE KEYPAD
To program the SK-1123-FQ, first determine the following information:
1. The master code Allows the system administrator to program or operate the keypad.
2. The user code or codes Allows users to use the keypad’s functions. Use the chart on pages 8
and 9 to organize.
3. Configuration of the relays and outputs For relay output #1 and output #2, determine whether the
output should operate from 1 to 999 seconds and then turn OFF (momentary mode), or turn
ON/OFF via the code (shunt mode). Use the chart on pages 8 and 9 to organize.
4. Result of improper code entry (optional) Choose between a 30-second code lockout, duress
output, a 15-minute code lockout, or no reaction.
*Note: When x x x x appears in the instructions, it indicates master code entry.
GETTING STARTED
A master code is required to program the keypad. The default master code is set to ―0000.‖ To change a
forgotten master code, go to page 15 and follow the instructions for ―MASTER CODE BYPASS‖
(DAP jumper).
Once the master code is set, review the programming options and decide exactly what the keypad will do,
including the format of the user access codes as well as how the keypad responds via the relay output,
buzzer and LEDs. Note that in every case the basic steps for programming are:
1. Enter the master code, followed by the key, which puts you in programming mode.
2. Enter the programming options defined in the various sections as needed, followed by the # key.
3. Enter the key again to exit programming mode.
Note: A rapid string of 5 beeps and/or 5 LED flashes indicates an error, while 2 beeps indicates that the
entry has been accepted.
USER PROGRAMMING
ENTER PROGRAMMING MODE
ADDING OR CHANGING MASTER AND USER CODES
WARNING Press the correct option key. If the option key is not used and a “0” is pressed after entering the
Master Code, it could accidentally reprogram the Master Code.
Option
User ID
Access Code
Confirm
Function
0
4 to 8 digits
#
Change Master Code
1
00 to 99
4 to 8 digits
#
Set/change up to 100 User Codes for output #1, with duress feature
2
0 to 9
4 to 8 digits
#
Set/change up to 10 User Codes for output #2
DELETE A USER
To delete a user who no longer has authority to enter the protected area:
Option
User ID
Confirm
Function
1
00 to 99
#
Deletes specific user ID from output #1
2
0 to 9
#
Deletes specific user ID from output #2
EXIT THE PROGRAMMING MODE BY PRESSING THE * KEY
WIRING, BASIC DIAGRAM
The ENFORCER SK-1123-FQ has backlit keys that can be programmed for different
applications. The keypad can be always illuminated (FULL), or illuminated only during user
activity (AUTO). To verify or change the settings, refer to the table below.
1
For DC, connect to a regulated power supply. Polarity of the regulated power supply must be correct. For AC,
polarity is not important.
2
Mantrap control output Outputs ground (-) for five seconds after relay output #1 is activated, continues while the
door is open.
3
Connect to ground (-) to prevent relay output #1 from operating, or to the mantrap (interlock) control output of
another keypad to disable output #1 while the other keypad is active.
4
Connect to optional N.O. push button or switch.
Page 4
Page 13
N.C. tamper
(+)
(-)
N.C
COM
N.O.
12~24V
VAC/VDC
Output 1
InterlockNPN transistor, used
with second keypad
2
(-) N.O. Output 1 inhibit
3
(-) N.C. Door position sensor
(-) Common groundfor use
with interlock function
(-)EgressN.O. ground
4
Duress outputTransistor
ground (-) 100mA@24VDC
(-) N.O. output 2
Note: User D must be entered for options 1 and 2.
Note: User D must be entered for options 1 and 2.
EGRESS
IN
N.C. tamper
DAP Jumper
Back-lit jumper
Back-Lit Jumper
Setting
Jumper Position
Description
FULL
(default)
Keypad standby mode is dimly backlit.
Keypad brightens to full illumination for 10 seconds
after each key is pressed, then returns to dim backlit
(standby mode).
AUTO
Keypad standby mode is not lit.
Keypad brightens to full illumination for 10 seconds
after each key is pressed, then turns off again
(standby mode).
1 2 3
1 2 3
Enter Master Code
Confirm
Function
x x x x
Enter into programming mode
1
3