Figure 8. Connecting Pump Hose to BCS Manifold
Figure 10. Connecting BCS Mix Bags (two bag
connection on left, one bag connection on right)
Figure 9. Completed BCS Hose Assembly
3-way Tee
ÆÆ
ÆÆ
Æ
C. Mix Low level Indicator Adjustment
The sensitivity of the "Mix Low" indication that
displays on the control panel can be adjusted to
operator preference. If more advanced notice of
low mix is required, simply loosen the black adjust-
ment knobs located on the sensor brackets at the
back of the freezer cabinet, and slide the bracket
upwards. If the "Mix Low" message appears while
there is still sufficient mix in the container, slide the
bracket downward. Be sure to tighten the adjust-
ment knobs after properly positioning the sensor
(see Figure 8).