A SERVICE OF

logo

Chapter 9 Incorporating Sun Blade X6250 Server Module Drivers Into WIM or RIS Images 65
Note For readability, the OemPnpDriversPath information has been shown on
multiple lines. The information must be entered on a single line.
9. Stop and start the Remote Installation Service (BINLSVC) on the RIS server.
To do this, type the following commands at the command prompt and press Enter
after each command:
net stop binlsvc
net start binlsvc
TABLE 9-2 Sun Blade X6250 Server Module .sif File Entries for Sun Blade RAID 5
Expansion Module
Windows Server 32-bit Windows Server 64-bit
[Unattended]
OemPreinstall = yes
OemPnpDriversPath=“\Sun\Drivers\
intel\chipset;\Sun\Drivers\intel\
nic;\Sun\Drivers\adaptec;\Sun\
Drivers\ast”
[MassStorageDrivers]
"Adaptec SAS/SATA-II RAID Controller
(32-bit)" = OEM
[OEMBootFiles]
adpenc.cat
adpenc.inf
arc.cat
arc.inf
arc.sys
arcsas.cat
arcsas.inf
arcsas.sys
ramdisk1
txtsetup.oem
[Unattended]
OemPreinstall = yes
OemPnpDriversPath=“\Sun\Drivers\
intel\chipset;\Sun\Drivers\intel\nic;\
Sun\Drivers\adaptec;\Sun\Drivers\
ast”
[MassStorageDrivers]
"Adaptec SAS/SATA-II RAID Controller
(64-bit)" = OEM
[OEMBootFiles]
adpenc.cat
adpenc.inf
arc.cat
arc.inf
arc.sys
arcsas.cat
arcsas.inf
arcsas.sys
ramdisk1
txtsetup.oem