Important!
The transformation of the appliance to use a
d i ff e r ent gas to that for which it has been
sold must only be carried out by a qualified
technician.
I n f o rmation for the Technical Serv i c e : in the
event of conversion of the type of gas or
p re s s u re in the appliance, the new re g u l a t i o n
label must be placed over the existing one, in
o rder to identify the new characteristics after
the changeover.
To make the transformation replace the gas
nozzles and regulate the minimum settings of
the taps.
The gas nozzles necessar y for each type of
gas are indicated in table 1.
To replace the gas nozzles it is necessary to
follow the following instructions:
• Remove the pan supports and the top part
of the burners in order to access the nozzle.
• Use a no 7 tubular spanner to remove
the nozzles and replace them with the
c o rresponding alternative nozzles. Take care
to tighten the nozzles well so as to avoid the
risk of gas leaks.
• Reposition the pan support and burn e r
covers.
Once the gas nozzles have been replaced, the
following instructions must be followed to
graduate the minimum settings.
Hob CG.1 4G, CG.1 3G 1P, CGC 4G y CGC 4G
AI AL
• Remove the oven or the control panel fro m
their place to access the gas taps.
• Light the burners at their minimum setting.
• Use a small screw driver to remove the
s c rew on the right or centre of the plug of
the gas key (turn left for a big flame and
right for a small flame).
• Once the setting has been graduated
check that the flame remains at its mini-
mum setting when the control is bru s q u e l y
t u r ned between the maximum and the
minimum setting.
14
Gas transformation
Table 1
CG LUX-60, CG LUX-70, CGC 4G, CG.1 4G, CG.1 3G. 1P.
CG Lux-75 and CG Lux-86
Burner Family
First Second Third
Group a Group c Group e Group H Group E+ Group 3+
Triple ring 290 290 290 135 135 95
Triple ring 5R (SHA) 340 340 340 - - -
Fast 260 260 260 116 116 85
Semi fast 185 185 185 97 97 65
Auxiliary 145 145 145 72 72 50
Gas nozzle diameter (Ø) expressed in 1/100 mm