A SERVICE OF

logo

THERMOSALD ISC – MANUAL QUICK START Rev. 2005 / 03
Manual cod.: 3ES080x_Vx_QS_EN Page Nr. 8 Tot. Nr . 8
2.2 ELECTRIC DRAW - POWER CONNECTIONS (CONTROL OF THE PRIMARY)
NOTE -
Power supply ( CN1/1 e CN1/4 ) must be with the same phase as
control supply ( CN2/3 e CN2/2 ).
Ground screw must be connected to the ground of machine, with the cable jellow green section
> = power cable section.
Twist power cable, twist TA cable
Twist and screen sealing reference cable