TOSHIBA G3 APPLICATION GUIDELINE 21.5
* For additional assistance, please contact Toshiba at (800) 231-1412 and ask for inverter marketing
Direction Change with RX Input (page 2 of 2)
Connections for bipolar reference
TERMINAL STRIP
ST CC F CC
RX CC
bipolar reference
Example programming for bipolar reference
Group Parameter New Value
UTILITY PARAMETERS Blind Function Selection 1
UTILITY PARAMETERS Frequency Setting Parameters Blind 1
FREQUENCY SETTING PARAMETERS Frequency Priority Selection #1 3
FREQUENCY SETTING PARAMETERS RX Terminal Standard or Adjustable 1
FREQUENCY SETTING PARAMETERS RX Reference Setting Point #1 -100 (default)
FREQUENCY SETTING PARAMETERS RX Point #1 Frequency -60
FREQUENCY SETTING PARAMETERS RX Reference Setting Point #2 100 (default)
FREQUENCY SETTING PARAMETERS RX Point #2 Frequency 60
NOTE: Never connect the ‘CC’ terminal to ground.