A SERVICE OF

logo

26
Adjustment of minimum level
Oven burner
Remove the top pan support as well as the
burner caps and the burner crowns.
Unscrew and remove the 2 top plate-fixing
screws and remove the top plate.
Light the burner knob on position 9 and leave
the oven door closed for about 10 min.
Turn the knob slowly to position 1.
Pull off the knob to adjust minimum flow.
Unscrew or screw the by-pass screw (is it
above of tap shaft) until a regular small flame
is reached.
For LPG, adjust the by-pass screw for
minimum flame setting.
The flame shouldn’t extinguish when closing the
oven door.
Grill burner
The grill temperature cannot be adjusted. To
obtain a lower temperature or slower cooking
time the grill pan must be lowered away from the
flame.
After completion of any repairs,
conversion or adjustments, the statutory
safety tests must be carried out.
by-pass