![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/0f/30fbbd75-2349-408e-9468-a325e5747356/30fbbd75-2349-408e-9468-a325e5747356-bg5.png)
9
Pre-drill two holes with 1/8” drill bit for the locators
using dimensions shown in the figure. Attach plastic
locators using the Torx (T20 BIT) pan head screws
provided in the hardware package.
Pre-drill other four locations for wood screws
to attach the panel to the dishwasher door using
the dimensions shown in the figure.
Use locators to align the panel to the
dishwasher door holes.
Use non-marring clamps to hold custom panel in place.
Use the truss head 1-3/4” long screws provided in the
hardware package for the panel attachment.
Note: If you are using any special panel material
and that require special screws, always use a #8 1-3/4”
long truss head Torx stainless steel screws. The screws
MUST BE stainless steel to avoid corrosion.
Have the overlay panel constructed per dimensions.
The panel thickness MAY NOT exceed 3/4" (1.91 cm)
for flush installation in most cabinets. Ensure that the
design, construction, and installation of the panel
overlay and its handle mounting is sufficient to reliably
operate in this application with a maximum panel
weight of 18 lbs. (8.2 kg.) Custom panels should not
exceed 18 lbs. (8.2 kg.)
Custom Door Panel (Installation Option)
29-3/4”
(75.6 cm)
to
31-1/4”
(79.4 cm)
22-21/32”
(57.5 cm)
23-9/32"with trim
(59.1 cm)
or
23-7/8” without trim
(60.6 cm)
14”
(35.6 cm)
22-5/32”
(56.3 cm)
13-1/2”
(34.3 cm)
10-5/8”
(27.0 cm)
ø1/8” 4 places
(0.3 cm)
Locator
8
Custom Door Panel
(Specifications for FDB301/FDB451 Models)
Note: Back side of panel shown. Use caution not to drill through front of panel.
Note: If panels are made longer than 29-3/4” (75.6 cm), the door panel will be taller than dishwasher control panel.
Note: All hole location dimmensions should be measured from the bottom of the door per the illustration above.