DGCU105-4B DGCU165-5B DGCU155-6B
Cutout width 28-3/4”(73.0 cm) min. 34-1/2” (87.6 cm) min. 42-7/8” (108.9 cm) min.
to 29-7/8” (75.9 cm) max. to 35-7/8” (91.1 cm) max. to 44-1/8” (112.1 cm) max.
Cutout height 2-3/4” (7.0 cm)*
Cutout depth 19-11/16” (50.0 cm) min. to 20-1/2” (52.1cm) max.
Surface burner rating
Left front 14,000 BTU Nat. (4.1 kW)/ 12,000 BTU Nat. (3.5 kW)/ 12,000 BTU Nat. (3.5 kW)/
13,500 BTU LP (4.0 kW) 11,500 BTU LP (2.8 kW) 11,500 BTU LP (2.8 kW)
Left rear 12,000 BTU Nat. (3.5 kW)/ 10,000 BTU Nat./LP (2.9 kW) 8,000 BTU Nat./LP (2.1 kW)
11,500 BTU LP (2.8 kW)
Right front 6,000 BTU Nat./LP (1.8 kW) 6,000 BTU Nat./LP (1.8 kW) 8,000 BTU Nat./LP (2.1 kW)
Right rear 8,000 BTU Nat./LP (2.1 kW) 8,000 BTU Nat./LP (2.1 kW) 6,000 BTU Nat./LP (1.8 kW)
Center 14,000 BTU Nat. (4.1 kW)/ 10,000 BTU Nat./LP (2.9 kW)
13,500 BTU LP (4.0 kW)
Right center 14,000 BTU Nat. (4.1 kW)/
13,500 BTU LP (4.0 kW)
*Top of grate support should be 1-1/8” (2.8 cm) above countertop. There must be a 1” (2.5 cm) clearance undercounter on all sides of the cooktops.
COOKING
Designer Built-In Gas
30”/36”/45”W. Ceramic Cooktop
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
UTILITY
REQUIREMENTS
GAS
• Must be ordered
from the factory
either natural gas or
LP/propane (DGCU
models are not field
convertible). Specify
LP after model
number and color
code, for example,
“DGCU155-6BSSLP”
• Accepts standard
residential 1/2”
(1.3 cm) ID gas
service line
• Gas manifold
pressure
• Natural gas 5.0”
W.C.P.
• LP/propane 10.0”
W.C.P.
ELECTRICAL
• 4-foot (121.9 cm)
cord included with
cooktop
• 3-wire with ground/
3-prong plug
• 120 V/60 Hz
• Max. amp usage—2.0
• *If electrical power is
not supplied or is
interrupted, the
open top burners
can be lit manually
with a match.
PLUMBING
Not applicable
Installation Requirements
ACCESS REQUIREMENTS