ERA & EBD SERIES ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
COOKING CONTROLS
1. Open fryer section door(s).
2. Remove electrical connection to cooking
controls.
3. Remove screws securing controls.
4. Remove cooking control cover.
5. Disconnect lead wires from the component
being replaced then remove from control box.
6. Reverse procedure to install and check for
proper operation.
DISCARD VALVE SWITCH
(KLEENSCREEN FRYERS ONLY)
1. Open the door to the fryer section being
serviced.
2. Disconnect lead wire connector.
3. Remove switch mounting screws.
4. Remove discard valve switch.
5. Reverse procedure to install and check for
proper operation.
NOTE: Switches are not adjustable.
TEMPERATURE PROBE
Do not sharply bend and kink, or clamp
down on the capillary tube or damage may occur.
1.
Raise heating elements.
2. Remove clamps from temperature probe.
F25385 (May 2010) Page 6 of 32