Chapter 2 Hardware Description and Connection
GS1100 Series User’s Guide
18
2 Align the holes on the back of the Switch with the screws on the wall. Hang the
Switch on the screws.
The Switch should be wall-mounted horizontally. The Switch's side
panels with ventilation slots should not be facing up or down as
this position is less safe.
2.3.2 Rack Mounting
The Switch can be mounted on an EIA standard size, 19-inch rack or in a wiring
closet with other equipment. Follow the steps below to mount your Switch on a
s t a n d a r d E I A r a c k u s i n g a r a c k - m o u n t i n g k i t .
Rack-mounted Installation Requirements
Two mounting brackets.
Eight M3 flat head screws and a #2 Philips screwdriver.
Four M5 flat head screws and a #2 Philips screwdriver.
Failure to use the proper screws may damage the unit.
Precautions
Make sure the rack will safely support the combined weight of all the equipment
it contains.
Make sure the position of the Switch does not make the rack unstable or top-
heavy. Take all necessary precautions to anchor the rack securely before
installing the unit.