VES-1000 Series Ethernet Switch
Hardware Installation 2-3
Figure 2-2 Mounting the VES-1008 in a Rack
2.2.3 Wall Mounted
The VES-1008 is designed so that it can be mounted on a wall if the need arises. The following is needed in order
to mount the VES-1008 on a wall:
• Two mounting brackets (supplied).
• Eight M3 flat head screws (supplied) and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Before you mount the VES-1008, please take note of the following precautions:
Precautions
• Make certain that the intended position for the VES-1008 is strong enough to support the combined
weight of the unit and the cables. It is strongly recommended that you position the VES-1008 so
that the brackets are screwed into an upright beam, or stud, that is located within the wall.
• Make certain that when mounted, you will be able to safely insert the Telco-50 cable along with the
power supply and then be able to safely monitor and observe the LEDs on the VES-1008.
Step 1. Position a mounting bracket on one side of the VES-1008, lining up the four screw holes on the bracket
with the screw holes on the side of the unit (Figure 2-3).