Sleep current test
5. After idle current checked, Switch OFF
the unit. Unit is turn off and no display.
sleep current value must under 6.35mA, if
over the criteria, it means M/B failed,
please replace M/B for repair.
Conclusion:
If current consumption is passed at both of idle and sleep mode, it means M/B is GOOD. If
there is any item FAILED at idle or sleep mode, it means M/B is failed, please replace M/B