49. Gently open the ex connector. Avoid putting pressure to
the components.
50. Lift up the glued inTOP FLEX , beginning at the shown side...
51....continue at the large connector. 52. If all adhesive parts are released, the Top FLEX ASSY can be
removed easily.
53. Keep this adhesive clean if this part should be reused.
Remove any adhesive residues on the opposing part.
54. Open the ex connector of the CAMERA FLEX MODULE.
55. Now the CAMERA FLEX MODULE can be removed together
with the CAMERA MODULE.
56. Slightly bend the D-COVER in order to release the clip. Do not
touch the components or the spring contact.