User interaction with SIM AT
DISPLAY TEXT
Text of up to 240 characters (80 UCS coded) is
supported.
‘Key’ responses
‘Long NO’ – Proactive session terminated by
user.
‘NO’ – Backward move in proactive session.
Any other key clears display if the command is
performed successfully.
GET INKEY
Prompt for a one-character input. Pressing ‘YES’
without entering a character gives warning mes
-
sage “Minimum 1 character”.
‘Key’ responses
‘C’ clears current character.
‘Long NO’ terminates the proactive session.
‘NO’ – Backward move in proactive session.
‘YES’ – Command performed successfully.
GET INPUT
Prompt for character input. Pressing ‘YES’ without
entering a character gives warning message “Mini
-
mum ‘no.’ characters”. The phone will refuse to
accept further input when maximum response
length is exceeded.
MMI Maximum Response lengths
Digits Only – 160 characters
SMS default alphabet characters – 160 charac-
ters
Hidden Characters (digits only) – 40 characters
'02' = Call disconnected Yes
'03' = Location status Yes
'04' = User activity No
'05' = Idle screen available Yes
'06' = Card reader status No
'07' = Language selection Yes
'08' = Browser termination Yes
'09' = Data available No
'OA' = Channel status No
SET UP IDLE MODE TEXT Yes , 1
row of
text is
sup
-
ported
SET UP MENU Yes
SMS PP DOWNLOAD Yes
Service Mode Support
in T290i/
T290c