2 –Pump 18-Station Controllers Chapter 3: Installation 17 of 44
Setting Up Stations
Before starting the system, you must define several settings for each station, such as which
pump conveys material to it. This section first discusses how to use the controller’s menu
system to configure stations. The table on pages 35–36 discusses the individual choices. To
set up each station, perform the following:
1. Go to the “Station Status” screen if needed. To reach this screen press station status
button on the Main Menu.
Figure 4: “Station Status” Screen
Because of the limited viewing space of the controller screen, you will need to press
MORE to view pumps 10-18.
2. On the “Station Status” screen (Figure 4), touch the icon for the station you want to
setup, and hold it for several seconds. The “Station Operator” screen opens.
Figure 5: “Station Operator” Screen Before Setup
This screen allows the operator to specify the amount of time that the station will
convey, unload, and purge material and also view the amount of time since it had
conveyed material last. Touching any white box in the lower half of the screen provides
you with a keypad to set new values (See page 15 for keypad entry instructions). From
this screen, the operator can also configure the convey settings for each station by
pressing NEXT or PREV (The screen above shows the settings for Station 1).